Capteur NDIR à diffusion à sortie analogique et numérique
- Manufacturer
- Smartgas
- HTTS ref.
- HTS-OPT-0014
- HTDS ref.
- CAPTEUR NDIR A DIFFUSION A SORTIE ANALOGIQUE ET NU
- Division
- Optoélectronique

Description
CONNECT smartMODUL // Technical Data Infrared gas sensor for diffusion with analogue and digital interfaces Infrared gas sensor using dual beam technology, with measurement and reference channel, for monitoring room air and process control applications
Key features
- Grande Précision
- Excellente sélectivité
- Durée de vie > 10 ans
Technical specifications
- Accuracy
- ≤ ±2 % FS 1
- Humidity
- 0 % to 95 % rel. humidity (not condensing)
- Telephone
- +49 (0) 7131/797553-0 | Telefax: +49 (0) 7131/797553-10 | www.smartgas.eu | [email protected]
- 0-2000 ppm
- C1-030205-00000
- Dimensions
- 72 mm x 55 mm x 34 mm (L x W x H)
- Gas supply
- by diffusion
- Resolution
- 1 ppm to 0.01 Vol.% FS 1
- ammonia NH
- 0-3.5 Vol.-% C1-200356-00000
- smartMODUL
- // Technical Data
- 0-20 Vol.-%
- C1-212207-00000
- Calibration
- zero by jumper / SW and span by jumper
- methane CH4
- 0-4.4 Vol.-% (0-100 % LEL) C1-040446-00000
- Air pressure
- 950 to 1050 mbar
- Maximum load
- 125 Ω
- Warm-up time
- < 2 minutes (start up time)
- propane C3H8
- 0-1.7 Vol.-% (0-100 % LEL) C1-050176-00000
- Repeatability
- ≤ ±2 % FS 1
- ethylene C2H4
- 0-2.4 Vol.-% (0-100 % LEL) C1-030246-00000
- Supply current
- 70 mA average, max. 140 mA
- Supply voltage
- 12 - 28 V DC ± 5 %
- n-butane C4H10
- 0-1.4 Vol.-% (0-100 % LEL) C1-020146-00000
- Linearity error
- ≤ ±1 % FS 1
- Measurement range
- dependent on model – see list
- Power consumption
- < 1 Watt
- refrigerant R404a
- 0-2000 ppm C1-740205-00000
- carbon monoxide CO
- 0-2 Vol.-% C1-221206-00000
- Response time (t90)
- Appr. 30 s
- Storage temperature
- -20 °C to 60 °C
- Digital output signal
- Modbus ASCII via RS485
- Lower detection limit
- ≤ 1 % FS 1 (typically)
- Measurement principle
- Non Dispersive Infra-Red (NDIR), dual wavelength
- Operating temperature
- -10 °C to 40 °C
- Analogue output signal
- 0 - 20 mA linear
- pentafluoroethane R125
- 0-2000 ppm C1-720205-00000
- Temp. dependence (span)
- ≤ ±0.2 % FS 1 per °C
- Temp. dependence (zero)
- ≤ ±0.01 % FS 1 per °C
- tetrafluoroethane R134a
- 0-2000 ppm C1-710205-00000
- sulphur hexafluoride SF6
- 0-1000 ppm (0-100 % TLV) C1-600105-00000
- • Dual beam technology
- acetylene C2H2 0-2.3 Vol.-% (0-100 % LEL) C1-010236-00000
- chlorodifluoromethane R22
- 0-2000 ppm C1-700205-00000
- Long term stability (span)
- ≤ ±2 % FS 1 over 12 month period
- Long term stability (zero)
- ≤ ±2 % FS 1 over 12 month period
- Pressure dependence (span)
- 0.1 % to 0.2 % per mbar 2
- Pressure dependence (zero)
- -
- • Gas entry by diffusion
- 0-5 Vol.-% C1-212506-00000
- dichlorotrifluoroethane R123
- 0-2000 ppm C1-730205-00000
- • Infrared measuring principle (NDIR)
- Gases * Measurement range Model type
- • Zero and span calibration by jumper
- carbon dioxide CO 0-5000 ppm (0-100 % TLV) C1-212505-00000
- • Analogue interfaces (e.g. 4 – 20 mA)
- 3
- * More gases and measuring ranges on request
- Sensors similar to the illustration
HTTSystems product sheet
Download the datasheet in our colours and contact details, or read it full screen.
Request a quote
Reference HTS-OPT-0014 is carried into your file. You fill in the context, an engineer takes it from there.
Request a quoteTalk to an engineer
A question about installation, consumables or compatibility before pricing? Our engineers answer from Douala.
Ask the questionClose to this one